-40%

Anritsu Site Master S251ACable & Antenna Analyzer SiteMaster

$ 514.79

Availability: 100 in stock
  • Country/Region of Manufacture: United States
  • Brand: Anritsu
  • MPN: S251A
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Frequency Range: 25-3300mhz
  • Condition: Seller refurbished
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • Refund will be given as: Money Back

    Description

    The Anritsu S251A Site Master is the instrument of choice for transmission line/antenna installation and maintenance. It is the best way to reduce maintenance expenses and improve quality. It replaces stacks of heavy, expensive and complex test equipment. Site Master's frequency domain reflectometry technique allows it to find problems before they become catastrophic faults thereby creating a huge cost savings. The Anritsu S251A Site Master uses a keypad to enter data and a liquid crystal display (LCD) to provide a graphical indication of S21, SWR, or RL over the selected frequency range. The Anritsu S251A Site Master has a built-in distance-to-fault (DTF) capability and is capable of up to two hours of continuous operation from a fully charged internal battery and can be operated from a 12.5 dc source (which will also simultaneously charge the battery). Built-in energy conservation features can be used to extend battery life over an eight-hour work day.
    Specifications
    Specifications
    Frequency Range
    625MHz - 2500MHz
    Frequency Accuracy (CW Mode)
    75ppm
    Frequency Resolution
    100kHz
    Immunity to interfering RF signals up to
    +2
    +10 dBm, Reflection / +30 dBc Transmission
    Return Loss
    Range - 0dB to 54dB, Resolution - 0.01
    Specifications:
    Frequency Range: 650-2500MHz
    Frequency Accuracy: (RF Source Mode) 75 parts per million @ 25°C*
    Frequency Resolution: 100 kHz
    SWR:
    Range: 1.00 to 65.00
    Resolution: 0.01
    Return Loss:
    Range: 0.00 to 54.00 dB
    Resolution: 0.01 db
    Test Port, Type N 50 Ohms
    ***Immunity to Interfering signals
    up to the level of: –5 dBm, reflection
    Maximum Input (Damage Level):
    Test Port, Type N: +22 dBm
    RF Detector: +20 dBm
    Measurement Accuracy:
    Measurement accuracy depends on calibration components. Precision calibration components have a directivity of 42 dB.
    Cable Insertion Loss:
    Range: 0.00 to 54.00 dB
    Resolution: 0.01 dB
    Frequency Reference
    Aging: ±1 ppm/yr
    Accuracy: ±2 ppm
    Internal Memory:
    Trace Memory: 40 maximum
    Instrument config.:
    10 setup locations
    RS-232: 9 pin D-sub, three wire serial
    Electromagnetic Compatibility Meets European community requirements for CE marking
    Power Supply:
    External DC Input: +11 to +15 Vdc, 1250 mA max.
    Temperature:
    Storage: –20° C to 75° C